UR C60

Interruptor de sistema de Protección. The C60 Breaker Protection System is a substation hardened controller that provides a complete integrated package for the protection, control, and monitoring of circuit breakers.
  • Detalles de Productos
  • Pregunta sobre este artículo

UR C60

alt
APLICACION MODELO TECNOLOGIA MARCA
Protección, Control y Registro UR C60 -- GE Multilin
FUNCION CODIGO SECCION
Controlador. 13-1202 13

 

DESCRIPTION

The C60 Breaker Protection System is a substation hardened controller that provides a complete integrated package for the protection, control, and monitoring of circuit breakers. The C60 supports dual-breaker busbar configurations such as breaker-and-a-half or ring bus arrangements. Signals from up to 4 sets of CT’s can be brought into the C60 for internal summation.

. alt


Key Benefits

  • Complete breaker control, monitoring and integration in a single platform
  • Complete IEC 61850 Process Bus solution providing resource optimization and minimizing total P&C lifecycle costs
  • Reduced wiring through the use of high-speed peer-to-peer communication for accepting Trip and Close commands from other relays
  • Advanced automation capabilities for providing customized protection and control solutions
  • Ambient temperature monitoring with alarming when outside temperature exceeds upper thresholds
  • Robust network security enabling Critical Infrastructure Protection through user command logging, and dual permission access control
  • Modular hardware architecture allows for flexibility in device configurations to cover most breaker applications
  • Advanced fault and disturbance recording, including internal relay operating signals thus eliminating the need for external recording devices
  • Simplified system integration with communications supporting serial, Ethernet and multiple protocols
  • Embedded IEC61850 Protocol
  • The C60 supports English, French, Russian, Chinese and Turkish languages on the front panel


Applications

  • Stand-alone breaker monitoring and control
  • Multiple breaker configuration control including Breaker-and-a-Half and Ring Bus
  • Automatic Bus Transfer scheme using a single device
  • As part of a distributed bay controller
 